PINNACLEBoard connectors / demo

DEMO — fictional range. Local brief only, NOT SENT. No personal data is collected or transmitted.

INSPECTION

Press depth and pull-out are the two checks.

A board connector is inspected at the bench rather than in service, because the joint it makes cannot be seen afterwards.

Illustrative inspection checklist

Press depth
Measured against the tool setting, on the first and last of a run
Pull-out force
On samples, per the declared table for the cable used
Conductor alignment
Conductor one to pin one, checked before termination
Coplanarity
Pin height across the row, because a lifted pin misses its socket
Insulator
Free of flash at the pin entry, which would displace a contact
Plating
Present and undamaged by the press
Shell continuity
Measured on shielded parts, because the bond is the function
Marking
Batch identifier legible on the part or its packaging

An illustrative checklist for a fictional range. A real programme defines the tolerance, the sampling method, the inspection window and the remedy if a batch fails.

The four things a programme needs in writing.

The tolerance, the sampling method, the window in which inspection happens, and what happens if the batch fails. Without all four, a failed delivery becomes an argument rather than a process.

Why coplanarity is on the list.

Because a pin that sits high does not enter its socket, and the connector still looks seated. It is a moulding and pressing issue rather than a contact issue, which is why it is checked separately.